Allowable working pressures [psi] for conveying water in Pexgol pipes, with a design factor DF = 0.8; safety factor C = 1.25
th
Design Temperature°CDesign Temperature °FSeries (S)
86.25543.152.5
SDR
1713.51197.36
1050154197247308391493
2068138176220276350441
3086121154193241306386
40104107137171214272342
5012295122152190242305
6014087111139174221278
701587799123154196247
801766887109136173218
90194617897121154194
95203587493116147186
100212506480100127160
10522141526582104131
1102303747597393117